{"id":6156,"date":"2024-11-27T05:06:50","date_gmt":"2024-11-27T05:06:50","guid":{"rendered":"https:\/\/dchhk.com\/?p=6156"},"modified":"2024-11-28T07:28:48","modified_gmt":"2024-11-28T07:28:48","slug":"he-thong-luu-tru-nhiet-nha-may-lam-lanh-trung-tam","status":"publish","type":"post","link":"https:\/\/dchhk.net\/en\/he-thong-luu-tru-nhiet-nha-may-lam-lanh-trung-tam\/","title":{"rendered":"THERMAL STORAGE SYSTEM \u2013 CENTRAL COOLING FACTORY"},"content":{"rendered":"<p class=\"has-text-align-center has-vivid-red-color has-text-color has-link-color has-large-font-size wp-elements-f688db283254fbebe3de4d8b0c7e54c3 wp-block-paragraph\"><strong>THERMAL STORAGE SYSTEM \u2013 CENTRAL COOLING FACTORY<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"752\" src=\"https:\/\/dchhk.com\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-1024x752.jpg\" alt=\"\" class=\"wp-image-6157\" srcset=\"https:\/\/dchhk.net\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-1024x752.jpg 1024w, https:\/\/dchhk.net\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-300x220.jpg 300w, https:\/\/dchhk.net\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-768x564.jpg 768w, https:\/\/dchhk.net\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-1536x1128.jpg 1536w, https:\/\/dchhk.net\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-2048x1504.jpg 2048w, https:\/\/dchhk.net\/wp-content\/uploads\/2024\/11\/so-do-cooler-01-16x12.jpg 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-a878ad992edff88146cf0f88db4c423e wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\">A thermal storage system typically consists of tanks of chilled water or ice that store the cooling energy produced by central refrigeration plants during periods of low energy demand. The stored cooling energy is then used during periods of peak demand or when the main cooling system is down. This approach not only balances the energy load but also improves the reliability of the cooling system.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-center has-text-color has-link-color has-large-font-size wp-elements-742328371c23b36e7e235d1e8fba587e wp-block-paragraph\" style=\"color:#060673\"><strong>BENEFITS OF THE SYSTEM<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left has-vivid-red-color has-text-color has-link-color has-medium-font-size wp-elements-2f25535999eb123e060b0e6de79d9753 wp-block-paragraph\"><strong>Increase energy efficiency<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-207984a99526e92ed229fa3b3780fc07 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Power transmission: <\/strong>The system allows chillers to operate during off-peak hours when electricity prices are lower. This process involves producing chilled water or ice, which is stored and used during peak hours. For example, at night, when energy demand is low, chillers can operate at maximum efficiency to produce and store chilled water.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size wp-elements-a7e5a9d30f34992d6d9dd9113bba274a wp-block-paragraph\" style=\"color:#060673\"><strong>Peak Shaving: <\/strong>By using stored cooling energy during peak hours, the system reduces demand on the grid, resulting in significant cost savings. This is especially beneficial for large Data Centers where energy costs can be very high.<\/p>\n\n\n\n<p class=\"has-text-align-left has-vivid-red-color has-text-color has-link-color has-medium-font-size wp-elements-074a923f2ac0ee4d2b7fa0dd74d484c9 wp-block-paragraph\"><strong>Increased reliability and redundancy<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-55682d0dabfa6a237c9b4ab7d36418e1 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Backup cooling: <\/strong>In the event of a chiller failure or maintenance, the thermal storage system will provide an immediate alternative cooling source, ensuring continuous operation of the Data Center. For example, if a chiller fails during peak operating hours, the stored chilled water can maintain the cooling load until the chiller is repaired.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-df58f5a958a6ab739dfb981642f5b73b wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Power failure response: <\/strong>The system can provide cooling power during power outages, which is critical to preventing IT equipment from overheating. This is especially important for a Hyperscale Data Center, where any downtime can result in significant financial and operational losses.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-vivid-red-color has-text-color has-link-color has-medium-font-size wp-elements-ade94a4c8ce2580ecdc3ac0c20ea1fda wp-block-paragraph\"><strong>Save operating costs<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-fd51cfb6275d44db40de152fd253d8fb wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Save operating costs <\/strong>By shifting energy consumption to off-peak hours, the system reduces overall energy costs. For example, a data center can take advantage of lower nighttime electricity prices to produce and store chilled water, which is then used during peak daytime hours.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-12dab6b39c9861841fc2ee0b26a3df02 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Deferred capital expenditure: <\/strong>The system can delay the need for additional chiller capacity, optimizing capital expenditure over time. As the Data Center expands, additional cooling capacity can be added gradually through the thermal storage system without requiring large-scale investment up front.<\/p><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color has-link-color has-medium-font-size wp-elements-0ef51372323f9e71c28ca36ee1b4bbe0 wp-block-paragraph\"><strong>Sustainable environment<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-7498f6da10a0364c7c4c5142f2587d1b wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Energy optimization: <\/strong>The system maximizes energy usage, aligns with sustainability goals, and reduces the Data Center\u2019s carbon footprint. By operating chillers at optimal efficiency and storing excess cooling energy, the system reduces waste and increases overall energy usage.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-918619f04ea7f6c3555139c3c675cb44 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Emission reduction: <\/strong>Reducing the need for supplemental cooling during peak demand periods will reduce greenhouse gas emissions associated with electricity generation. For example, by reducing reliance on grid power during peak demand periods, Data Centers can reduce their environmental impact.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-49ee8148542f286d6bc13e30430a0082 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Optimized chiller operation: <\/strong>Operating chillers during off-peak hours allows them to operate at their most efficient levels, reducing wear and tear and extending their life. This also reduces maintenance requirements and costs.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-f5a3cf237008135911765fed1df6c1ad wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Temperature control: <\/strong>Stable and reliable cooling ensures that IT equipment operates within optimal temperature ranges, improving performance and longevity. Thermal storage systems provide a stable cooling environment, reducing the risk of overheating and hardware failure.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-center has-vivid-red-color has-text-color has-link-color has-large-font-size wp-elements-99c9f30e2fa31209017fb97d06e3af39 wp-block-paragraph\"><strong>DCH DIGITAL HUB DATA CENTER THERMAL STORAGE SYSTEM \u2013 COLD WATER TANK<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/dchhk.com\/wp-content\/uploads\/2024\/11\/DCH-47-01.png\" alt=\"\" class=\"wp-image-6158\" srcset=\"\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" data-srcset=\"\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-81fbfd65d0b521dcf0758d8fa69c686c wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Size and capacity: <\/strong>The Digital Hub Data Center, with a total IT load capacity of 75MW, will benefit significantly from the scalability of the thermal storage system. Each Data Center hall is designed with a dedicated thermal storage system \u2013 a cold water tank, ensuring that cooling needs are met efficiently. For example, each Data Center hall has 1,200 racks with a total IT load capacity of 15MW, requiring powerful and reliable cooling solutions.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-01591a9cbbf3a59c1e0b3b33d1f45015 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Centralized cooling factory: <\/strong>The central chiller plant in this project consists of 12 medium voltage chillers in a 10+2 (N+1) redundant configuration, providing a total cooling capacity of 84.4 MW plus 16.8 MW of standby. The ice storage system, powered by three dedicated chillers, can store and provide cooling energy for at least 12 hours at full load, ensuring uninterrupted service during peak load periods or chiller maintenance.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-39d345218dd9e16440e90ab9ccdfef80 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-justify has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>Energy saving: <\/strong>By using thermal storage, the Data Center can take advantage of lower energy levels during off-peak hours, reducing overall energy costs. For example, at night, the chiller can produce and store chilled water for use during peak daytime hours, resulting in significant cost savings.<\/p><\/p>\n\n\n\n<p class=\"has-text-align-left has-text-color has-link-color has-medium-font-size wp-elements-9916570489f507d951e6bf0a95a4ed52 wp-block-paragraph\" style=\"color:#060673\"><p class=\"has-text-align-JUSTIFY has-text-color has-link-color has-medium-font-size\" style=\"color:#060673\"><strong>In summary, integrating thermal storage with the central chiller plants in this Data Center project will improve energy efficiency, reliability, cost savings and environmental sustainability. It ensures the facility can meet cooling needs efficiently while supporting operational and sustainability goals, making it a robust and future-proof solution for large-scale Data Centers.<\/strong><\/p><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>H\u1ec6 TH\u1ed0NG L\u01afU TR\u1eee NHI\u1ec6T &#8211; NH\u00c0 M\u00c1Y L\u00c0M L\u1ea0NH TRUNG T\u00c2M M\u1ed9t h\u1ec7 th\u1ed1ng l\u01b0u tr\u1eef nhi\u1ec7t th\u01b0\u1eddng bao g\u1ed3m c\u00e1c b\u1ec3 ch\u1ee9a n\u01b0\u1edbc l\u1ea1nh ho\u1eb7c n\u01b0\u1edbc \u0111\u00e1, l\u01b0u tr\u1eef n\u0103ng l\u01b0\u1ee3ng l\u00e0m m\u00e1t do c\u00e1c nh\u00e0 m\u00e1y l\u00e0m l\u1ea1nh trung t\u00e2m s\u1ea3n xu\u1ea5t trong th\u1eddi gian nhu c\u1ea7u n\u0103ng l\u01b0\u1ee3ng th\u1ea5p. Sau \u0111\u00f3, [&#8230;]\n","protected":false},"author":1,"featured_media":6168,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[4,9],"tags":[],"class_list":["post-6156","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-du-an","category-du-an-noi-bat"],"_links":{"self":[{"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/posts\/6156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/comments?post=6156"}],"version-history":[{"count":4,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/posts\/6156\/revisions"}],"predecessor-version":[{"id":6181,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/posts\/6156\/revisions\/6181"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/media\/6168"}],"wp:attachment":[{"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/media?parent=6156"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/categories?post=6156"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dchhk.net\/en\/wp-json\/wp\/v2\/tags?post=6156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}